en
0 | FSA 70 | Initial start-up
4.
Initial start-up
4.1
Mounting
1.
Remove the packaging of all delivered parts.
2.
The FSA 720 must be permanently fastened to the
worktop (workbench) using the supplied retaining
panel, or mounted to a wall or a mobile base (trol-
ley). When assembling the weight of the sensors and
the center of gravity must also be taken into account.
If the FSA 720 is to be mounted onto a mobile base,
we recommend mounting it to a trolley (available as
supplementary equipment set 1 687 001 586).
If the FSA 70 is upturned then people may
be injured or material damage occur.
Always secure the FSA 720 against tipping
over, as in principle there is a risk that
anyone tripping up or pulling on the sensors
may pull the unit over.
4.
Initial operation FSA 70
Prior to starting up for the first time make sure that the
lighting mains supply voltage matches the voltage spec-
ified on the power pack (100 V – 240 V, 50/60 Hz).
i
The delivery specification includes the German
mains connecting cable. Other country-specific
mains connecting cables are not part of the delivery
specification.
4.3
Turning on and off
The voltage supply is established directly by way of the
power pack. The FSA 720 does not have an ON / OFF
switch.
1.
Plug in power pack connecting cable on the FSA 720
(Fig. 2; Item 9).
2.
Plug USB connecting cable into FSA 720
(Fig. 2; Item 7).
Secure USB connecting cable and power pack con-
3.
necting cable on the retaining panel with two cable
ties for strain relief (Fig. 3, Item 1).
KV-
COM
15+
- 1
Fig. 3: Strain relief on the retaining panel
1 Cabel tie
4.
Plug USB connecting cable into PC.
5.
Connect power pack to lighting mains.
|
1 689 979 894
2007-01-30
X
D
KV+
CH1
CH2
15V DC
USB
459775/11Ko
1
4.4
Connecting the sensors
Connect sensors to designated slots in measuring unit
(see Fig. 2). Only connect current clamps 30 A and 1000
A and adapter cable 1 684 465 513 when required.
4.5
Software installation CompacSoft[plus]
i
Before starting installation check the system require-
ments. The FSA 720 can only be operated using a PC
with the CompacSoft[plus] software installed.
i
The software installation can be undertaken without
the FSA 720 hardware connected.
i
For Windows
2000 and XP only.
®
1.
Close all open applications.
Place CD "CompacSoft[plus]" into DVD disk drive on PC.
2.
i
In this installation example the DVD disk drive has
been assigned the disk drive letter D:.
In the toolbar use the button to select the
3.
menu.
4.
In the Start menu select the Run menu option.
The Run window is opened.
In the entry box Open: type in
5.
confirm with the "OK" button.
6.
Follow the instructions on the screen.
After installation of the system software the
FSA 720 is ready for measuring.
and
D:\RBSETUP
Bosch Diagnostics