11. ADJUSTING THE NEEDLE GUARD
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the following
work after turning the power off and ascertaining that the motor is at rest.
0.1 to 0.15mm
MS-1261/V045
{
}
MS-1261/V046
0.05 to 0.1mm
MS-1261M/V045
{
}
MS-1261M/V046
(0.05 to 0.1 mm for MS-1261M/V045, MS-1261M/V046)
0.1 to 0.15 mm
– 6 –