Testing Of The Appliance - Angelo Po 0G1FT2E Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CONVERSION OF ELECTRICITY SUPPLY
The appliance is supplied at an operating voltage
400V/3N (indicated on the sticker applied to the da-
taplate); conversion to 230V/3 can be carried out as
described below.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
1 - Undo the screws (A) and remove the guard (B).
2 - Modify the connections to the heating element
terminals (C) as shown in the electrical system
diagram at the back of the manual.
3 - Fit the jumper (D) to make the electrical con-
nection of the terminals (E-F).
4 - Replace the guard (B) and retighten the
screws (A).
5 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used
Important
On completion of the operation make sure
that there are no malfunctions.

TESTING OF THE APPLIANCE

Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
B
To test the system, make the following checks.
1 - Check that the mains voltage is the same as
that of the appliance.
2 - Operate the appliance's circuit-breaker to
check the electrical connection.
3 - Check that the safety device is operating cor-
rectly.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.