Hofmann EEWB746A Manual Del Operador página 107

Tabla de contenido

Publicidad

107
7-3
Trouble shooting
Code C12
Readings of numbers of measuring runs
Example: 222,123 measuring runs so far performed
(Fig. 7-3).
The following counters can be displayed:
1 = Total number of measuring runs
2 = Number of measuring runs where balance
quality was considered oK
3 = Number of optimisations or minimisations
4 = Number of measuring runs in service mode
5 = Number of measuring runs since the last
calibration.
6 = --
Every measuring run actually completed is stored.
Maximum count is 999,999 runs. once this number is
reached, the counter is reset to zero.
The information is primarily useful for statistical
purposes, e. g. to obtain evidence of load intervals of
parts when defective, or of monthly (yearly) use of the
machine, etc. The measuring runs performed while
the machine is on are transferred into the permanent
memory and added when it is switched off. The counter
cannot be reset.
Code C13
Starting the mesuring run by closing of wheel
guard
0* = Start via START key
1 = Start via wheel guard
The selected mode of operation can be transferred to
the permanent memory.
Code C14
Readjustment of the machine by the operator
See Section 6-2. Readjustment by the operator.
* = Factory adjusted mode
Operator's Manual