Operation
Reading of error code E9
if E9 is read out, at least one error was made with respect
to the sequence of operations when performing optimisation
(see Paragraph 7.1 System messages).
Abort the optimisation program by pressing the STOP
key and, if desired, start optimisation once again.
Fig. 5-49 oPTiMiSATioN "OP.12"
(4th measuring run of tyre/rim assembly)
Clamp the wheel on the balancer.
Rotate the wheel such that the valve is exactly
perpendicular to and above the main shaft.
Confirm the valve position by pressing menu key F1.
The oPTiMiSATioN "oP.13" screen (Fig. 5-50) is
displayed.
Fig. 5-50 oPTiMiSATioN "OP.13"
START is displayed on the screen.
Press the START key.
A measuring run is performed.
BALANCiNG screen
The
Finish weight minimisation / optimisation
BALANCiNG
Fig. 5-51
if the wheel running conditions are optimal, the following
codes can be displayed (Fig. 5-52):
H0 Wheel running conditions cannot be improved by
optimisation.
H1 Further optimisation not recommended but feasible.
H2 Weight minimisation is recommended, optimisation can
achieve no further improvement.