Maintenance
6.0 Maintenance
This unit is designed to operate for a long time.
if the operator shuts down correctly (Section 5.2.4)
at the end of each shift, no further maintenance is
required.
This unit must not be opened by the operator, except
in accordance with explicit instructions.
6.1
Compensation Run
All clamping and centring means are balanced in our
works to within a certain tolerance.
To compensate for any residual unbalance that might
be left in the clamping means, it is recommended
that an electrical compensation run be performed
after switching on the machine or after changing the
wheel adaptor, especially a motorcycle wheel adaptor.
This mode cannot be transferred into the permanent
memory.
Application:
Fit the clamping device properly on the balancer
shaft. Do not fit the wheel.
Starting from the MAiN MENu press the menu key
F2 three times
(Fig. 6-1)
of unbalance and select the menu key F2 (Fig.
6-2) for Compensation Run.
The C4 screen (Figure 6-3) will open.
Start the Compensation Run with the START key.
The Compensation Run takes longer than a regular
measuring run. After the Compensation Run, an icon
in the status Bar indicates the Compensation Active
status (1, Fig. 6-4).
This mode of operation is retained until deleted by
- pressing menu key F2 (Fig. 6-2) again and rotating
the wheel until 0 will be displayed, thus by pressing
F6,
- by starting readjustment
- or an optimisation run,
- or by switching off the machine.
Operator's Manual
for electrical compensation
EEWB746A