Operation
5.2 Preparation
• The operator should be familiar with the warnings
and cautions.
• The operator should be qualified to work with the
unit.
• Always ensure that the wheel guard is lifted and the
gauge arm is in its home position (far left position)
when the unit has been switched off.
5.2.1 Power up
• Do not keep any key pressed down during power
up.
Refer to Fig. 5-3.
• insert the power cable plug in the mains socket
"1".
• Set the switch on the socket to the "i" position.
Note:
if the unit beeps and does not proceed or
if an error code is shown, refer to Chapter
7.
The unit will beep and perform a self-test
The display and the weight position indicators relating
to the current weight mode will stay on (default).
Refer to Figure 4-4 for an example.
The unit is now ready to receive input.

5.2.2 Status at switching on

The electronic unit is factory-adjusted to the following
modes of operation, which are available after switching
on:
vehicle type 1 (car wheel with nominal dimensions
in inches, width 6.5" and diameter 15.0")
entry of rim data in inches
display of amount of unbalance in 5-g
increments
suppression of minor unbalance readings (limit
set to 3.5 g)
automatic braking of wheel when guard is
opened during the measuring run
compensation of adaptor unbalance switched
off
start of measuring run by START key (1, Fig.
4-15).
Operator's Manual
now.
EEWB746A