4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Pressing <-> with the display turned off means an impulse of P.P.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
mENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Motor 1 work time. Regulates the maximum duration of the opening and closing
TM1
manoeuvre of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Motor 2 work time. Regulates the maximum duration of the opening and closing
TM2
manoeuvre of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
The operating time for partial opening (pedestrian) is adjusted on motor 1.
With ENC.: ON, the value is the opening percentage over the total stroke memorised
TPed
during self-setting.
With ENC.: OFF, the value is the opening percentage over the time preset in TM1
parameter.
PMo1
The torque applied to motor 1 in the OPENING* phase is adjusted.
PMC1
The torque applied to motor 1 in the CLOSING* phase is adjusted.
PMo2
The torque applied to motor 2 in the OPENING* phase is adjusted.
PMC2
The torque applied to motor 2 in the CLOSING* phase is adjusted.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
TLS contact activation time.
TLS
At each manoeuvre the contact closes for the set time.
Electric lock activation time.
TLOc
If the electric lock is not used, set the parameter at 0.
Motor 1 slowing time
Regulates the duration of the slowing phase of motor 1 on opening and closing.
TsM1
Value is calculated as a percentage on the space covered during the complete ope-
ration. 0 = slowing time disabled.
Motor 2 slowing time
Regulates the duration of the slowing phase of motor 2 on opening and closing.
TsM2
Value is calculated as a percentage on the space covered during the complete ope-
ration. 0 = slowing time disabled.
Pso1
The torque applied to motor 1 during braking in the opening phase is adjusted *
PsC1
The torque applied to motor 1 during braking in the closing phase is adjusted *
Pso2
The torque applied to motor 2 during braking in the opening phase is adjusted *
PsC2
The torque applied to motor 2 during braking in the closing phase is adjusted *
14
NOTES
PARAmETERS, LOGIC AND SPECIAL FUNCTIONS
FUNCTION
Settable values
mEmO
mIN-mAX-(Default)
1-240-(40s)
5-180-(24s)
5-180-(24s)
1-99-(50%)
1-99-(40%)
1-99-(40%)
1-99-(40%)
1-99-(40%)
0-15-(2s)
0-40-(3s)
1-240-(60s)
0-5-(3s)
0-99-(0%)
0-99-(0%)
1-99-(70%)
1-99-(70%)
1-99-(70%)
1-99-(70%)