The intervention threshold of the anti-crashing device (Encoder) during the phase at
SeaU
normal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
The intervention threshold of the anti-crashing device (Encoder) during braking is
SEAR
adjusted *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
** WARNING: AN INCORRECT SETTING OF ThESE PARAmETERS mAY RESULT IN A DANGER.
COmPLY WITh REGULATIONS IN FORCE!
mENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
Off: condominium function disabled.
IbL
On: condominium function enabled. The step-by-step impulse or transmitter impulse
has no effect during the opening phase.
The bloc of flat function is enabled or disabled.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter
IbCA
signal has no effect during the TCA counting.
Off: the bloc of flat function is disabled.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the intervention
SCL
of the photocell causes automatic closing after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
Enables or disables slowing.
Sld
On: Slowing active.
Off: Slowing excluded.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enables or disables the inversion stroke function
On: Function enabled. Before each opening or closing manoeuvre the control unit
HAM
orders a manoeuvre of 2s in the opposite direction to facilitate the release of the
electric lock.
Off: Function disabled.
Enables or disables the block maintaining function.
Recommended for hydraulic motors to keep the leaf resting against the mechanical
stop block.
BLC
On: Block maintaining function enabled. Every 2 hours the control unit makes a clos-
ing manoeuvre with a duration of about 3s to keep the leaf in contact.
Off: Block maintaining function disabled.
Enables or disables starting torque function.
On: Starting torque enabled. At the start of each manoeuvre for 2s the motor oper-
SPN
ates at maximum torque.
Off: Starting torque disabled.
Selects the operating mode of the blinking light during the time TCA
LTCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
Selects the mode of the OPEN input
On: OPEN input with CLOCK function.
CLOC
To be used for connection to a timer for timed opening/closing. (Contact CLOSED-
gate open, Contact open, normal operation).
FUNZIONE
FUNCTION
Valori impostabili
mEmO
ON-OFF-(Default)
0-99-(0%)
0-99-(0%)
Settable values
mEmO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
15