Setup; General Setup Diagram; Meanings Of The Various Parameters - SOMFY Dexxo Pro 800 RTS Manual De Instrucciones

Ocultar thumbs Ver también para Dexxo Pro 800 RTS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15

SETUP

General setup diagram

Meanings of the various parameters

Code
Description
P0
Total operating mode
P1
Orange warning light
P2
Safety input
P3
Obstacle detection
sensitivity
P4
Partial operating mode
P5
Closing speed
P6
Partially open position
P7
Closure approach speed
P8
Opening speed
P9
Choice of operating direction
(type of door)
Fig.
31
Values
0: sequential
1: sequential + timed close
2: automatic closure
3: automatic closure by cells
0: without advance warning
1: with 2 s advance warning
0: no safety mechanism
1: safety mechanism with self test
2: safety mechanism without self test
0: low sensitivity
1: low sensitivity
2: standard
3: high sensitivity
0: sequential
1: sequential + timed close
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
By default, 6: approx. 12 cm/s
Storing the position as illustrated in Fig. 33.
0: no slowdown
1: short soft stop
2: long soft stop
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
0: direction 1: all types of doors except
swinging doors
1: direction 2: swinging doors
Comments
Each press on the remote control causes the motor to move (initial position:
door closed) as per the following cycle: open, stop, close, stop, open...
In sequential mode with automatic timed close:
- the door is closed automatically after the timed delay
programmed in parameter "t0",
- pressing a button on the remote control interrupts the
movement taking place and the timed close.
In automatic closure mode:
- the door is closed automatically after the timed delay
programmed in parameter "t0",
- pressing a button on the remote control during
Automatic closure
opening has no effect,
mode operation
- pressing a button on the remote control during closing
is only possible if
causes it to reopen,
photoelectric cells
- pressing a button on the remote control during the
are fitted, i.e. P2=1
timed close restarts the timed delay.
or P2=2.
After the door is opened, movement in front of the cells
(safe closure) will close the door after a short timed
delay (fixed at 5 seconds).
If there is no movement in front of the cells, the door will
close automatically after the timed close programmed in
parameter "t0".
If there is an obstacle in the cells' detection zone, the
door will not close. It will close once the obstacle is
removed.
If the garage opens onto a public road, always select with advance
warning: P1=1.
If value 0 is selected, the safety input is not taken into account.
If value 1 is selected, the system's self test is run at the start of every
operating cycle.
If value 2 is selected, the safety system runs without a self test: it is essential
to test its proper operation every six months.
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure or install a sensor bar.
Each press on the remote control causes the motor to move (initial position:
door closed) as per the following cycle: open, stop, close, stop, open...
Automatic closure mode operation is only possible if photoelectric cells are
fitted, i.e. P2=1 or P2=2.
In sequential mode with automatic timed close:
- the door is closed automatically after the timed delay programmed in
parameter "t2",
- pressing a button on the remote control interrupts the movement taking place
and the timed close.
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure or install a sensor bar.
P7=0: the door does not slow before closure.
P7=1: the door speed slows 20 centimetres before closure.
P7=2: the door speed slows 50 centimetres before closure.
If this setting is changed, it is essential to run the force measurement
sequence at the end of the installation procedure or install a sensor bar.
If this setting requires modification the end limit setting must be repeated along
with self-learning.
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dexxo pro 1000 rts

Tabla de contenido