EN
1.10
Control panel
1
1
FUNCTIONAL BUTTONS
y
If pressed once or more than once for at least 1 second
during normal operation, this button allows the user
to change the boiler operating mode in a cyclical
sequence (Stand-by – Summer – Winter). If the boiler is
experiencing a fault which can be reset, it allows boiler
operation to be unblocked.
r
During normal operation, pressing the button displays
the domestic hot water set point which can be between
10 and 60°C. In "parameter setting", the user can scroll
through the parameter index (decreasing) by pressing
this button.
t
During normal operation, pressing the button displays
the heating set point which can be between 20 and
80°C. In "parameter setting",
through the parameter index (increasing) by pressing
this button.
<
During normal operation, pressing this button allows
the user to reduce the heating or DHW set point on
the basis of the selection made previously. If there is a
Remote Control (Open Therm), after having selected the
heating button, the user can modify the incline of the
climatic curve (decreasing it) by pressing the button ( - ).
In "parameter setting/display", the user can modify the
parameter setting or value (decreasing) by pressing this
button.
>
During normal operation, pressing this button allows
the user to increase the heating or DHW set point on
the basis of the selection made previously. If there is a
Remote Control (Open Therm), after having selected the
heating button, the user can modify the incline of the
climatic curve (increasing it) by pressing the button ( + ).
In "parameter setting/display", the user can modify the
parameter setting or value (increasing) by pressing this
button.
c
Programming connector cover plug.
2
Fig. 6
the user can scroll
pressing any one of these buttons for more than 30
NOTE:
seconds generates a fault on the display without preventing
boiler operation. The warning disappears when normal
conditions are restored.
DISPLAY
2
l
. This symbol appears when the boiler is
"SUMMER"
operating in "Summer" mode or if only the domestic
hot water mode is enabled via the remote control. If the
symbols
l
and
n
are flashing, this indicates that the
chimney sweep function is active.
n
. This symbol appears when the boiler is
"WINTER"
operating in "Winter" mode or if both the domestic hot
water and heating modes are enabled via the remote
control. With the remote control, if no operating modes
have been enabled both symbols
d
. The message indicates that after
"RESET REQUIRED"
having repaired the fault, normal boiler operation can be
restored by pressing the button
r
"DOMESTIC HOT WATER"
a DHW request or during the "chimney sweep function"
It flashes during the selection of the domestic hot water
set point.
t
"HEATING"
. This symbol lights up during heating
operation or during the "chimney sweep function It
flashes during the selection of the heating set point.
f
"BLOCK" DUE TO NO FLAME
F
.
"FLAME PRESENCE"
v
. This indicates the power level at which
"POWER LEVEL"
the boiler is operating.
p
. This indicates that the user may be in
"PARAMETER"
parameter setting/display, or "info" or "counter", or in
"activated alarms" (history).
A
. This indicates that a fault has occurred. The
"ALARM"
number specifies the cause which generated the alarm.
z
. This indicates that the "chimney
"CHIMNEY SWEEP"
sweep function" has been activated.
e
. This indicates that the external
"EXTERNAL SENSOR"
sensor has been installed and that the boiler is working
on a sliding temperature.
a
"HEATING SYSTEM PRESSURE"
pressure.
E
"ECO", ALTERNATIVE ENERGY SOURCES
indicates that there is a solar system available.
l
and
n
will be off.
y
.
. This symbol is present during
.
. Display of heating system
. Where active, it
75