3.3
Parameter setting and display
To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
r
and
the same time until "PAR 01" (parameter number) and the
value set (0÷4) appears on the display
– press the button
t
to scroll up the list of parameters and
then
r
to scroll down the list
3.4
List of parameters
Type
No.
Description
Index showing boiler power in kW
0 = 25T
PAR
01
1 = 25/55
3 = 30/55
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or heating only
2 = hot water tank with sensor
PAR
02
3 = bithermic
4=instant with solar power input
5 = open vent
6 = boiler with heat pump
Gas Type Configuration
PAR
03
0 = G20; 1 = G31
Combustion configuration
PAR
04
0 = sealed chamber with combustion control
PAR
08
External sensor value correction
PAR
09
Ignition fan speed
PAR
10
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
PAR
11
-- = Disabled
PAR
12
Heating Curve Incline
PAR
13
Minimum Heating Temperature Adjustment
PAR
14
Maximum Heating Temperature Adjustment
PAR
15
Maximum power heating
PAR
16
Heating Post-Circulation Time
PAR
17
Heating Pump Activation Delay
PAR
18
Re-ignition Delay
Domestic Hot Water Modulation with Flow meter
PAR
19
0 = Disabled
1 = Enabled
PAR
20
Maximum power domestic hot water
PAR
21
Minimum power heating/domestic hot water (premixed)
Domestic hot water preheating enabling
PAR
22
0 = OFF; 1 = ON
External relay 1 function
0 = not used; 1 = remote alarm NO; 2 = remote alarm NC; 3 = zone valve; 4
PAR
23
= automatic filling; 5 = external request; 6 = recirculation pump; 7 = zone
valve with OT; 8 = relaunch pump; 9 = boiler with heat pump (circulator)
88
t
(for approximately 5 seconds) at
DOMESTIC HOT WATER - HEATING
holding the buttons
NOTE:
scrolling movement.
– once the required parameter has been reached, press the
buttons
>
or
<
to modify the value within the permitted range.
The modifications are stored automatically.
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
t
all at the same time
screen is displayed.
CONFIGURATION
80 .. 160
0 .. +10
20 .. PAR 14
PAR 13 .. 80
0 .. 100
0 .. 100
0 .. 100
r
or
t
increases the speed of the
for at least 5 seconds until the initial
Range
U/M
Step
0 .. 4
-
1
0 .. 6
-
1
0 .. 1
-
1
-
-
-
-5 .. +5
°C
1
RPMx25
1
°C
1
-9 .. +5
°C
1
0 .. 80
-
1
°C
1
°C
1
%
1
seconds
0 .. 99
1
x 10
seconds
0 .. 60
1
x 10
0 .. 60
Min
1
0 .. 1
-
1
%
1
%
1
0 .. 1
-
1
0 .. 9
-
-
EN
r
Default
1 or 3
2
0
0
0
128
3
-2
20
20
80
100
3
0
3
1
100
0
0
0