Fault / malfunction codes

Type
No.
Description
ALL
02
Low water pressure in system
ALL
03
High water pressure in system
ALL
04
Domestic hot water sensor fault
ALL
05
Delivery sensor fault
ALL
06
No flame detection
ALL
07
Safety thermostat intervention
ALL
08
Fault in the flame detection circuit
ALL
09
No water circulating in the system
ALL
10
Auxiliary sensor fault
ALL
11
Gas valve modulator disconnected
ALL
12
Incorrect configuration of the open /sealed chamber
ALL
13
Smoke probe intervention
ALL
14
Smoke probe fault
ALL
15
Fan check cable disconnected
ALL
18
Condensate level fault
ALL
28
Maximum number of consecutive releases
ALL
30
Return sensor (SR) fault
ALL
37
Fault due to low network voltage
ALL
40
Incorrect network frequency detected
ALL
41
Flame loss more than 6 consecutive times
ALL
42
Button fault
ALL
43
Open Therm communication fault
ALL
44
No flame valve opening time sum anomaly
ALL
62
Self-calibrating procedure is required
ALL
72
Incorrect positioning of the delivery sensor
ALL
77
EV2 SGV current max/min absolute limits error
ALL
78
EV2 SGV current upper limit error
ALL
79
EV2 SGV current lower limit error
Fault on the valve control logic line/valve cable
ALL
80
damaged
ALL
81
Block due combustion during start-up
ALL
82
Block due to numerous combustion control failures
ALL
83
Irregular combustion (temporary error)
Flow rate reduced for (presumed) low pressure on
ALL
84
mains gas
ALL
88
Internal error (board component protection)
ALL
89
Unstable combustion feedback signal error
ALL
90
Combustion set cannot be reached error
System has reached maximum air correction error
ALL
92
(at the minimum flow rate)
ALL
93
Combustion set cannot be reached error
ALL
95
Flame signal micro interruptions error
ALL
96
Block due to clogging in smoke outlet
ALL
98
SW error, board start-up
ALL
99
General board error
90
3.6

Display of operating data and counters

Once the boiler is operating a qualified technician can view the
operating data and the counters as follows:
– from the operating screen in the mode enabled at that
moment (WINTER
n
or SUMMER
– go into "DISPLAY" by pressing the buttons
for more than 3 seconds until the following screen
same time
appears
From this point, the technician has 2 options:
– scroll through the list of "information (PAR)" and "counters
by pressing the button
(PARc)"
– display the "activated alarms" (no more than 10) by pressing
the button
r
– Once in this section, proceed with button
When all the values have been displayed, exit the menu by
pressing and holding down the button
seconds until the initial screen is displayed.
EN
l
)
r
and
<
at the
t
. Scrolling will be in sequence
t
or
r
.
y
for approximately 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Brava slim he 30/55 erp81142168114218Brava slim he 25/55 erp

Tabla de contenido