Fault
With the power
switched on, the pump
does not run
46
Cause
MCB tripped/defective.
FI protection switch has
tripped.
Undervoltage
Damage to the windings
Terminal box defective.
capacitor defective
(only for 1~).
Terminal box type
4a and 4d
Speed selection plug is
not fitted.
Terminal box type
4b, 4c and 4d
Remedy
Exchange/switch on the MCB.
If the MCB trips again:
• Check the pump for electrical
defects.
• Check the mains cable to the
pump and check the electrical
connections.
Switch on the FI protection switch.
If the FI protection switch trips
again:
• Check the pump for electrical
defects.
• Check the mains cable to the
pump and check the electrical
connections.
Check the voltage at the pump
(refer to the name plate).
Ask for after-sales
Ask for after-sales
Exchange the capacitor.
Fit the speed selection plug.