English
Minimum inlet pressure (above atmospheric pressure) at the pump suction port
in order to avoid cavitation noises (at fluids temperature T
SCX/SXM/DCX/DXM
T
Rp ¾
Med
+50 °C
0.05 bar
+95 °C
0.5 bar
+110 °C
1.1 bar
+130 °C
2.4 bar(*)
(*) not applicable to SXM 25-90, SCX/DCX 80-110 et 80-150
NSB-S, SXS
T
Rp ¾
Med
+50 °C
0.5 bar
+80 °C
0.8 bar
+110 °C
2.0 bar
The values apply up to 300 m above sea level; addition for higher locations:
0.01 bar/100 m increase in height.
5.3 Scope of delivery
• Pump, complete
• Two seals for threaded connection
• Two seals and bolts for flange connection
• Eight M12 washers
(for M12 flange bolts for DN 32-DN 65 combination flanged version)
• Eight M16 washers
(for M16 flange bolts for DN 32-DN 65 combination flanged version)
• Installation and operating instructions
5.4 Accessories
Accessories must be ordered separately:
• Change-over switch for 3~230 V
• Kit-press 6 or Kit-press 16
34
Rp 1
Rp 1¼
DN 32/40
Rp 1
Rp 1¼
DN 50
DN 65
0.3 bar
1.0 bar
1.6 bar
2.9 bar(*)
DN 40
DN 50
0.8 bar
1.0 bar
3.0 bar
):
Med
DN 80
DN 100
DN 65
DN 80
Salmson 02/2012