Union loose
➥ Tighten the union
Pipe cracked
➥ Replace the pipe
Switch broken
➥ Clean or replace the switch
Solenoid valve stuck
➥ Clean or replace the solenoid valve
Oil leakage inside the distributor
➥ Replace the distributor
Gaskets worn
➥ Replace the gaskets
Overload cut motor protector activated
➥ Open the electric system box by loosening the screws that hold the closure hooks,
then reactivate the overload cut-out by raising the grey bar (A fig.39). At the end,
reclose the electric system box.
Current does not arrive to the solenoid valve
➥ Check the electric connection to the solenoid valve
Solenoid valve blocked
➥ Clean or replace the solenoid valve
Transformer fuse broken
➥ Replace the fuse
Control lever incorrectly calibrated
➥ Call the service centre
Batteries run down (red LED on) (only in the radio versions)
➥ Charge the batteries
➥ Replace disposable batteries