Connections - Panasonic WV-CS570 Manual De Instrucciones

Ocultar thumbs Ver también para WV-CS570:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CONNECTIONS

Precautions
• The following connections should be made by qualified service personnel or system installers in accordance
with all local codes.
• See the reverse side of the cover page for main lead connection.
Note:
When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing opera-
tion).
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line
#24
Copper wire size
(AWG)
(0.22mm
Length
(m)
of cable
(ft)
(approx.)
Accessory Connector Information
Pin no.
Power source
1
24 V AC LIVE
2
24 V AC NEUTRAL
3
Ground
4
Not use
How to Assemble the Cable with the Accessory
Connector
Strip back the cable jacket approx. 3 mm (0.1 inch) and
separate the individual conductors.
Approx.
Approx.
3 mm (0.1 inch)
3 mm (0.1 inch)
Up A
Up
Contact
Contact
220 V - 240 V AC (WV-CS570)
24 V AC (WV-CS574E)
Data port
Video output
Alarm out
✻ The coaxial cable length (RG-59/U, BELDEN 9259) for the connection
is up to 1 200 meters (4 000 ft.)
#22
#20
2
)
(0.33mm
2
)
(0.52mm
2
)
20
30
45
65
100
160
4
2
Wire
Wire
Insert
Insert the wire until A position
Insert the wire until A position
and clamp the contacts.
and clamp the contacts.
BNC plug
Alarm in
Prepare the individual conductors for clamping. Use
MOLEX band tool part number 57027-5000 (for UL-
Style Cable UL1015) or 57026-5000 (for UL-Style
UL1007) for clamping the contacts.
#18
After clamping the contacts, push them into the proper
(0.83mm
2
)
holes in the accessory connector of this camera until
75
they snap in place.
260
3
1
CAUTIONS
• Shrinking the cable-entry seal is a one-time proce-
dure. Do not shrink the cable-entry seal until ascer-
taining that the unit is functioning.
• CONNECT THIS TO 24 V AC CLASS 2 POWER SUP-
PLY ONLY.
-17-
24 V AC cable
RS485 cable
Coaxial cable
To VIDEO IN
(CAMERA IN)
BNC plug
To sensors
To indicators
Up
Up
Contact
Contact
Wire
Wire

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Wv-cs570gWv-cs574e

Tabla de contenido