USE
3.3.

Donning the Respiratory Protection Device

The unit can be donned using a few simple hand movements in about 20 seconds
as follows:
10
Hanging the S-Cap-Air around the neck
(1) Hang the carry bag around the neck by the
black neck strap.
The inspection window of the bag should point
outwards and the thumb loop should point
down and to the right.
Opening the bag / starting the unit
(2) Insert the thumb of the right hand in the yellow
thumb loop of the carry bag and hold the bag
securely.
(3) Hold the yellow unzipping loop in the left hand
and pull firmly upwards. This pulls out the
start-up pin from the valve of the compressed
air cylinder valve, opening it. The air flow is
audible.
Attention!
This action starts the air supply which lasts
for 15 minutes.
(4) Check that the start-up pin is clear of the valve
cap, if not; fully unscrew the valve cap from the
valve.
Donning the hood with the half-mask
(5) Insert both hands in the 'prayer' position into
the hole in the neck seal and then move them
apart spreading the neck seal.
(6) Slide hands and hood down over the head.
(7) Adjust the half mask position on the chin and
nose and press securely to locate.
(8) Check the neck seal for secure sealing.