Technical Data - MSA S-Cap-Air Manual De Funcionamiento

Equipo de protección de aire comprimido para escape con capucha
Ocultar thumbs Ver también para S-Cap-Air:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
MSA
9.

Technical Data

Weight
Method of carrying
Storage temperature
Service life
Breathing air
Temperature of the
inhalation air
Air supply time
GB
With 3L 200 bar steel cylinder: approx. 6 kg
With 3L 300 bar COMPOSITE-cylinder: approx.
< 5 kg
On the chest with neck harness
-15°C to +50°C
Hood and tubing:
if stored according to ISO 2230: 10 years
Steel cylinder:
Check intervals in accordance with national
regulations
COMPOSITE-cylinder: 15 years (see Label)
Check intervals in accordance with national
regulations.
In accordance with EN 12021 or USCGA grade D
Corresponding to the storage temperature
15 minutes
S-Cap-Air
TECHNICAL DATA
19

Publicidad

Tabla de contenido
loading

Tabla de contenido