Alarm
AL07
Unit temperature
probe interrupted
in short circuit
AL08
Unit
overtemperature
Unit flow meter alarms
AL09
Flow meter Alarm
84 |
Cause
The alarm is enabled
if the boiler temperature
probe reads the minimum
range and is therefore
interrupted
The alarm is enabled if the
boiler temperature probe
reads a temperature hi-
gher than 120°
The alarm is enabled if at
least 100 pulses are not
counted in the first 5 sec
during brewing
Effect
The unit heating function is disabled;
the boiler continues working.
The alarm display is canceled by pres-
sing the encoder but the unit remains
inhibited until the next POWER ON
The unit heating function is disabled; the
boiler continues working.
The alarm display is canceled by pressing
the encoder but the unit remains inhibi-
ted until the next POWER ON
Brewing is not interrupted but the Led of
the selected dose flashes. Alarm enabled
only on the 2 dosed selections. Alarm reset
by setting the lever to the stop position