6. START-UP PROCEDURE

1) Check that the power supply cord is disconnected.
2) With the Front Panel (Left) removed, check that
the Operation Switch on the Control Box is turned
on.
Front Panel
(Left)
Air Filter
Fig. 5
Circuit
Motor
Breaker (6A)
Protector (3A)
Control Box
Fig. 6
3) Replace the Front Panel (Left) and Top Panel in
their correct position.
4) Open the water supply tap.
5) Connect the power supply and energise.
6) The following should occur in sequence:
a) Water Reservoir will fill.
b) Gear Motor will start.
c) Compressor will start.
IMPORTANT
1. Check the conditions and quality of the ice
production.
2. Do not use ice produced in the trial run. It
might be contaminated with foreign matter in
the water circuit. Discard or flush down the
drain.
3. Clean the Storage Bin before use (see "III. 1.
CLEANING" in Instruction Manual).
Control Box
Condenser
Operation
Switch

7. FINAL CHECKS

1) Is installation free of water leaks?
2) Is the icemaker free from vibration?
3) Are all the panels fixed and secure?
4) Has the user been instructed on correct machine
use and handed the Instruction Manual?