Hydraulic Connections; Plumbing Accessories (Optional); Gas Supply - Sime Brava Slim BF Manual De Instalación Y Mantenimiento

Calderas murales de baja temperatura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

m
CAUTION
– The height of the boiler is to be such that disassembly
and maintenance interventions are facilitated.
2.9

Hydraulic connections

The plumbing connections have the following characteristics
and dimensions.
=
65 65 65 65
M
U
G
E
L
Description
M - System delivery
R - System return
U - Domestic hot water output
E - Domestic hot water inlet
G - Gas supply
L (mm)
76
=
95
R
Brava Slim BF
25
30
Ø 3/4" G
Ø 3/4" G
Ø 1/2" G
Ø 1/2" G
Ø 3/4" G
400
450
2.9.1

Plumbing accessories (optional)

To facilitate plumbing and gas connections to the systems, the
accessories as shown in the table below are available and are to
be ordered separately from the boiler.
DESCRIPTION
Installation plate
Curve kit
Curve and valve kit with connections from DIN
to SIME
Cocks kit
Valve kit with connections from DIN to SIME
Wall mount replacement kit for other makers
Solar kit for instant combination boilers
Fitting protection Kit (25 kW)
Fitting protection Kit (30 kW)
Polyphosphate dosing kit
Dosing recharge kit
kit instructions are supplied with the accessory itself or
NOTE:
are to be found on the packaging.
2.10

Gas supply

Brava Slim BF
boilers leave the factory specifically prearranged
for G20 gas or G30/G31. The G20 models can be converted to
function with G30/G31 using the "specific nozzle kit" (optional)
provided by Sime on request separately from the boiler.
If changing the type of gas to be used, carry out the entire "GAS
phase of the appliance.
CONVERSION"
Boiler connection to the gas mains must be carried out in full
compliance with installation Standards in force.
Perform the following checks before making the connection:
– check that the boiler is compatible with the type of gas supply
– the pipes are clean
– the gas supply pipe is the same dimension as or greater than
that of the boiler fitting (G3/4") and with a load loss less than
Fig. 12
or equal to that contemplated between the gas mains and the
boiler.
a
DANGER
Once installation has been completed, check that
the joints are air tight as indicated in the installation
Standards.
m
CAUTION
It is recommended that the gas line has a suitable
filter.
EN
CODE
8075441
8075418
8075443
8091806
8075442
8093900
8105101
8094530
8094531
8101700
8101710

Publicidad

Tabla de contenido
loading

Tabla de contenido