Programming Space Heating - Rotex RKHBRD011AAV1 Manual De Operación

Unidad interior para bomba de calor de aire-agua y elementos opcionales
Ocultar thumbs Ver también para RKHBRD011AAV1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87

Programming space heating

5 sec
RKHBRD011~016AAV1+Y1
Indoor unit for air to water heat pump system and options
4PW55803-1
Programming space heating is carried out as follows:
NOTE
1
Press the < button to enter the programming/consulting mode.
2
Select the operation mode you would like to program by means
of the pi and pj buttons.
The actual mode is blinking.
Press the < button to confirm the selected mode.
3
The actual day is blinking.
4
Select the day you would like to consult or to program by means
of the pi and pj buttons.
The selected day is blinking.
5
Press the < button to confirm the selected day.
Hold down the < button for 5 seconds to program the detailed
6
actions.
The first programmed action of the selected day appears.
7
Use the < button to select the action number you would like to
program or to modify.
Use the pi and pj buttons to set the correct action time.
8
9
Use the ébi and ébj buttons to set the leaving water
temperature.
10 Use the bi and bj buttons to set the room temperature.
11 Use the ba button to select:
-
-
Use the ébi and ébj buttons to set the appropriate
shift value (refer to "Space heating operation (h)" on page 4 for
more information about weather dependent set point).
12 Repeat steps 7 to 10 to program the other actions of the
selected day.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
13 Press the < button for 5 seconds to store the programmed
actions.
If the < button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.
You automatically return to step 6.
5 sec
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
14 You automatically return to step 6, start again to program the
following day.
Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the pr button.
x: to switch heating and the remote controller off.
a: to select automatic temperature calculation for leaving
water temperature
Operation manual
12

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido