Toxic Gas Measurements (Figure 2-4); Solaris Multigas Detector Equipped With An; No 2 Sensor Only; Warning - MSA Solaris Manual De Operación

Ocultar thumbs Ver también para Solaris:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Toxic Gas Measurements (FIGURE 2-4)

Figure 2-4. Instrument in Toxic Gas Alarm
The Solaris Multigas Detector can be equipped to detect:
Carbon Monoxide (CO) and/or
Hydrogen Sulfide (H 2 S) in the atmosphere.
When the alarm setpoint is reached for Carbon Monoxide (CO)
and/or Hydrogen Sulfide (H 2 S):
Alarm Sounds
Alarm Lights flash
PPM CO or PPM H 2 S flag above the concentration flashes.
If the Toxic Gas alarm condition is reached while using the
instrument as a personal or area monitor, leave the area
immediately; the ambient condition has reached a preset
alarm level. If using the instrument as an inspection device,
do not enter the area without proper protection. Failure to
follow this warning will cause over-exposure to toxic gases,
which can result in serious personal injury or death.
Solaris Multigas Detector
Equipped with an NO 2 Sensor Only
The Solaris Multigas Detector can be equipped to detect NO 2 .
Units are identified:
at turn-ON by displaying 'TOX2 NO2'
during continuous operation, by scrolling 'Solaris NO2' across the
display.

" WARNING

2-9

Publicidad

Tabla de contenido
loading

Tabla de contenido