Accessing The Instrument Setup Mode - MSA Solaris Manual De Operación

Ocultar thumbs Ver también para Solaris:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accessing the Instrument Setup Mode

1. Press and hold the RESET button while turning the instrument ON.
SETUP displays.
NOTE: In all of the following selections in this Set-up mode:
Press ON/OFF to enter chosen value/go to the next page.
Press the ON/OFF button to store the chosen value.
Press RESET to decrement by one or toggle ON/OFF.
Press and hold RESET to decrement by 10.
Press PAGE to increment by one or toggle ON/OFF.
Press and hold PAGE to increment by 10.
2. Enter password default "672".
3. Press ON/OFF to enter password.
Correct Password: instrument continues/beeps three times.
Incorrect Password: instrument enters the Measure mode.
4. Password ON/OFF (turns the password protection ON or OFF)
5. New Password Setup (changes the password)
6. Instrument Options Setup
Safe LED ON/OFF
Instrument Alarm Bypass Options Setup
Visual alarm ON/OFF (red LEDs)
Audible alarm ON/OFF (buzzer)
Vibrator ON/OFF
Backlight ON/OFF
Backlight timer (10 seconds to 10 minutes)
OP beep ON/OFF
STEL/TWA ON/OFF
Time (if data logging option installed)
Date (if data logging option installed)
CAL Due ON/OFF (if data logging option installed)
CAL Due duration (1 to 180 days)