Short Term Exposure Limits (Stel) (Figure 2-9); To Reset The Stel - MSA Solaris Manual De Operación

Ocultar thumbs Ver también para Solaris:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Turn-ON or
MIN reading was reset.
MIN appears in the upper portion of the display.
To reset the MIN Reading:
1. Access the Min page.
2. Press the RESET button.

Short Term Exposure Limits (STEL) (FIGURE 2-9)

Figure 2-9. Exposure Page with STEL Alarm
The STEL flag appear in the upper portion of the display to show
the average exposure over a 15-minute period.
When the amount of gas detected by the Solaris Multigas Detector
is greater than the STEL limit:
Alarm sounds
Alarm lights flash
STEL flashes.

To Reset the STEL:

1. Access the STEL page.
2. Press the RESET button.
The STEL alarm is calculated over a 15-minute exposure. Calculation
examples are as follows:
Assume the Detector has been running for at least 15 minutes: