Description of the unit / Technical specifications / Assembly
1.1
PrODUCt DESCrIPtION, ENvISAgED USE
AND FIELD OF APPLICAtION
T5-SB: electronic Aprimatic unit fitted with a microprocessor,
designed to operate and control a motor with maximum
power of 680 Watt, powered by a 230 V AC power supply
and used exclusively to control vehicle access road barriers
automatically.
Functioning of the unit is described in par.5 and 6.
With reference to the safety standards, unit logic and
functioning parameters can be set to ensure that unit
functioning matches requirements (see par.4).
The limits of use for the automatic device involved must be
adhered to (specified in the relevant instruction manual).
Information
Only use the product for the permitted uses
specified. Do not use the product for purposes other
than those specified.
Do not tamper with or modify the product.
The product must only be installed using APRIMATIC
material.
Aprimatic S.p.A. declines all liability for damages caused
by failure to follow these instructions
1.2
tECHNICAL SPECIFICAtIONS (tab.1)

technical specifications

Power supply voltage for accessories
Frequency
Power consumption (no load)
MAX unit consumption (motor and accessories connected
and functioning)
Operating temperature
Storage temperature
MAX relative humidity
Protection class
F1 - motor protection fuse
F2 - primary transformer protection fuse
F3 - external accessories protection fuse (24 V DC)
Maximum load of accessories
2.
ASSEMbLy
The unit can be wall-mounted or installed inside the barrier
body.
CAUTION! Installation inside the barrier body is only
recommended if suggested by the manufacturer of the
barrier.
Wall assembly
• Secure the unit at least 30 cm from the ground using
expansion bolts with diameter of 6 mm and the plastic
container securing holes.
• Insert the connection cable using the pre-marked holes
on the bottom of the container and the PG16 skintop cable
clamp.
IMPORTANT! Use cables suitable for outside use and follow
the instructions given in fig.2.
T5-SB unit
JP4
JP3
JP2
JP1
K9
DL8
K3
SW1
ON
1 2 3 4 5 6
K2
1
2
3
4
5
6
7
8
9
wall assembly
230 V AC (+6 % ; -10 %)
50 Hz
15 W
750 W
-20°C +70°C
-20°C +85°C
<90% non condensing
IP55 (only with IP55 housing)
6.3 A fast blow
200 mA fast blow
500 mA fast blow
500 mA
- 1 -
F3
P4
P2
P3
P1
RL1
JP5
K5
RL2
+ -
JP7
K1
10 11
12
13
14
15 16
installation inside
the barrier body
Fig. 1
DL1
F2
F1
K4
table 1