ADVANTAGE
4.1 Half mask
Cleaning and Care:
Clean and disinfect halfmask after every use. To
clean the half mask remove the filters (cleaning the
filters is not possible). Use a mild detergent in
lukewarm water and rinse with clear water and dry
air (max. 50°C).
Spare parts:
Spare parts are not provided.
Storage:
Only undamaged half mask must be stored for fur-
ther use. When not in use, store respiratory pro-
tective device in cool, dry and clean ambient air.
Shelf life:
The manufacturing date of the half mask is marked
inside. Example (see Fig. 7): Manufacturing date
April 2006
4.2 Filter
Filter
Proper Storage
Factory sealed gas or
combined filters:
Opened gas or combined
filters that are to be
reused:
Factory sealed particle fil-
ters:
Particle filters that have
been used against radio
active substances, micro
organisms or bio chemi-
cally active substances:
Factory sealed and properly stored MSA respiratory filters are
maintenance free.

5 Ordering Information

5.1 Half Mask
Description
Advantage 200 S
(small)
Advantage 200 M
(medium)
Advantage 200 L
(large)
5.2 Full Face Mask
Description
Advantage 3211 S
(small, textile neck strap)
Advantage 3221 M
(medium, textile neck strap)
Advantage 3231 L
(large, textile neck strap)
Advantage 3212 S
(small, silicone neck strap)
Advantage 3222 M
(medium, silicone neck strap)
®
200
-5 to 50°C, max. 90 % relative humidity for
long-term storage
Storage life: See information on the filters (pic-
togram "Hourglass")
In a closed plastic bag
5 to 35°C, max. 60 % relative humidity
Storage life: replace 6 months after first use at
the latest!
-5 to +50 °C, max. 90 % relative air humidity
(see pictograms)
Storage life: See information on the filters (pic-
togram "Hourglass")
Single use only, do not reuse!
No further storage.
Part No.
430357
430356
430358
Part No.
10027727
10027726
10027728
10042732
10042733
11
Advantage 3232 L
(large, silicone neck strap)
5.3 Respiratory protective filters
Attention!
Only use undamaged filters of the same type and class.
!
Always replace both filters at a time.
Filter
Description
20 P2
particle [pre-]filter
200 P3
particle filter
201 A
gas filters
201 K
gas filters
201 ABE
gas filters
201 ABEK
gas filters
202 A-P3
combination filters
202 K-P3
combination filters
202 ABE-P3
combination filters
202 ABEK-P3
combination filters
Tabtec A1
gas filters
Tabtec A2
gas filters
Tabtec A2B2E1K1 gas filters
Flexifilter P2
particle filter
Flexifilter P3
particle filter
Flexifilter P3-OR
particle filter
Adapter for
TabTec/
FLEXIfilter [pair]
* - national types are identical to European Standard, except of marking with R/NR
5.4 Accessories
Description
Advantage+Comfo half masks belt pouch
Covers, R95, ADV. 200,2/PKG
10042734
Filter type
Part No.
EN 143:2000 P2 R
10011347
GOST R 12.4.194-99 P2R
DSTU EN 143:2002 P2
EN 143:2000 P3 R
430375
GOST R 12.4.194-99 P3R
DSTU EN 143:2002 P3
EN 14387 A2
430371
GOST 12.4.235-2012 A2
DSTU EN 14387:2006 A2
EN 14387:2004 K2
10107163
GOST 12.4.235-2012 K2
DSTU EN 14387:2006 K2
EN 14387:2004 A1, B1, E1
10144827
GOST 12.4.235-2012 A1 B1 E1
DSTU EN 14387:2006 A1 B1 E1
EN 14387:2004 A2, B2, E1, K1
430373
GOST 12.4.235-2012 A2 B2 E1 K1
DSTU EN 14387:2006 A2 B2 E1 K1
EN 14387:2004 A2 P3 R
430372
GOST 12.4.235-2012 A2-P3 R
DSTU EN 14387:2006 P3
EN 14387:2004 K2 P3 R
10107165
GOST 12.4.235-2012 A1 B1 E1 P3 R
DSTU EN 14387:2006 K2 P3
EN 14387:2004 A1, B1, E1 P3 R
10144828
GOST 12.4.235-2012 A1 B1 E1 P3 R
DSTU EN 14387:2006 A1 B1 E1 P3
EN 14387:2004 A2, B2, E1, K1 P3 R 430374
GOST 12.4.235-2012 A2 B2 E1 K1 P3 R
DSTU EN 14387:2006 A2 B2 E1 K1 P3
EN 14387 A1
10030510
EN 14387 A2
10030511
EN 14387 A2, B2, E1, K1
10038476
EN 143:2000 P2 R
10027699
EN 143:2000 P3 R
10027639
EN 143:2000 P3 R
10027697
10030514
Part No.