ESBF-BS/-LS-32 ... 100
5.1.1
Mount product
Note
Pulling out of screws if cylinder is only mounted to the covers and the torque load
around the collar is too great.
If there are heavy loads, mount the cylinder to the profile with additional mounting
components.
Place ESBF as follows:
– all control sections are accessible
– Pressure compensating opening 4 (è Fig. 1) is not covered.
Interfaces for mounting components
on the cover
e.g. with flange mounting EAHH
8
Fig. 6
Select mounting components or accessories (è www.festo.com/catalogue).
Mount the mounting components outside the positioning range (avoid collisions).
Select mounting elements so that internal torques are braced against the housing during powerful
acceleration phases.
Mount cylinder without distortion and deflection.
Tighten screws 8 uniformly to the specified tightening torque.
Size
Screw
Tightening torque
Tab. 1
Note
If an EAGF guide unit is used:
Mount construction kits for proximity switches outside the mounting area of the
EAGF (è Assembly instructions).
Festo – ESBF-BS/-LS-32 ... 100 – 1504a English
on the profile
e.g. with profile mounting EAHF
32
40
8
M6
M6
[Nm]
6
6
corrie
50
63
80
M 8
M 8
M10
12
12
25
100
M10
25
23