•
After having removed the screw, you can take off
the interior cover. There is a coloured Plexiglas pane
under the cover; this pane can also be removed.
Figure 36.1
•
Then you can access the tube and replace it. Make
sure to replace the starter (
each tube replacement.
•
Installation is carried out in reverse order.
DECORATIVE TUBES IN ThE CANOPy (MS 4500)
•
The chromium facings of the "eyes" are only fixed with
Velcro tape. They can easily be removed by hand.
Figure 36.3
•
Undo the four screws fixing the carrier plate and lift
off the plate.
36
M a n u a l d e u s u a r i o | megaSun 4000 / 4500
with
figure 36.1, zoomed)
Figure 36.2
•
Pull the defective lamp carefully out of its fixture.
(Do not turn it!).
Figure 36.5
•
When inserting the new compact fluorescent lamp,
make sure that the lamp is correctly connected to
the fixture (see circle).
•
Fasten the carrier plate and ensure that the edge
of the diffusing panel
(figure 36.6)
the carrier plate.
Figure 36.6
•
At last, fix the chromium-plated facing.
Figure 36.4
is positioned below