Aroma connections

If you have opted for the Aroma function, the Aroma
box is fastened to the front left-hand foot in the base
section of the unit. The box is equipped with three
hose connections, one of them leading to the Aroma
tin
, the other two to the ventilation ducts of the
nozzles in the foot area
Figure 11.1
6
Aroma box (inlet)
7
Aroma box (outlets)
8
Compressor
9
Time relay
AROMA CONTROL
The "Aroma function" is controlled by a time relay.
Air is guided through the Aroma tin by means of a
compressor during the connection time. The scented
air is released into the tanning space from the foot
end.
The time relay is mounted on a plate at the front left-
hand foot of the sunbed. you can set the scenting
time and the break interval here.
The following switching times are preset at the
factory:
Connection time
Interval (break)
If in doubt about the setting procedure, have trained
service staff carry out the timing.
The studio customer cannot switch this function
on or off!
.
->
T on = 12 s
->
T off = 60 s
STRUCTURE OF ThE TIME RELAy
The Aroma relay includes 4 adjusting elements: two
rotary switches and two potentiometers.
Figure 11.2
T on
(connection
time)
T off
(Intervall)
The upper pair is used to set T on , the lower pair to
set T off
; the rotary switch is located above
(figure 11.2)
the potentiometer in both cases. A rotary switch and
a potentiometer together offer the setting options
available for T on or T off respectively.
SETTING ThE TIME RELAy
The following applies for both setting ranges (T on /
T off ):
Switching time = time factor * multiplier
Figure 11.3
Rotary switch
Potentiometer
Set the time factor (X) by using the corresponding
rotary switch. Specify the applicable multiplier (1-
10) by setting the potentiometer located below the
switch. -> X * 1; X * 2; X * 3...... - X * 10
Example:
Set a time factor of 6 seconds (6-60s) by means of a
rotary switch and select 2 as the multiplier with the
corresponding potentiometer. The switching time
resulting from this setting is 6 * 2 = 12 seconds.
M a n u a l d e u s u a r i o | megaSun 4000 / 4500
determines the
duration of the
Aroma spraying
cycle.
determines the
duration of the
break between
two spraying
cycles.
Setting of time
factor
Setting of multiplier