INSTALLING
DISCHARGE
PIPING
_WARNING
Do not use plastic pipe, soldered
copper
fittings, rubber hose, or lead-tin soldered
joints anywhere
in the compressed
air
sys_m.
z_ CAUTION
If you will be using synthetic
compressor
lubricant,
all downstream
piping material
and system components
must be
compatible.
Refer to the following
material
con_pedbig_
list. If there are Incom_,_lble
materials
present in your system,
or if
there are materials
not included
in the list,
contact Ingersoll-Rand
for
recommendations.
SYNTHETIC
COMPRESSOR
LUBRICANT
MATERIAL
COMPATIBILITY
LIST
SUITABLE
Viton®, Teflon®, Epoxy (GlaSs Filled), Oil Resistant Alkyd,
Fluorosilicone, Fluorocarbon, Polysulfide, 2-Conlpoflent
Urethane,
Nylon, Delbn®, Celcon@>High Nitrile Rubber (Buna N NBR more
t_an 36% Aetylonitrile), Polyurethane, Polyethylene,
Epich)orohydhn, Polyacry)ate, Melam)ne, Polyprepylene, Baked
Phenolies, Epoxy, Modified Alkyds (® indicates trademark of
DuPont Corporation)
NOT RECOMMENDED
l"_eoptone, tlat_i_
R_bbef, _BP. R_bel,
_,c_'_t e paul, Lsc_,
i
Varnish, Polystyrene, PVC, ABS, Poly_rbonate, C_llulose
Acetate, Low Nitdfe Rubber (Buna N NBR less than 36%
I
Acrylonitrile), EPDM, EthyleneVinylAeetata
Latex EPR Acrylics, I
Phenoxy, Polysulfones, Styrene Acrylonitrile (San), Butyl
i
NOTE
All compressed
air systems generate
condetlsate
which
accumulates
in any
drain point {e.g. tanks, fitters, drip legs,
aftercoolers,
dryers). This condensate
contains
lubricating
oll and/or
substances
which may be regulated
and must be
disused
of in accordance
with Ior_al,
state, and federal
laws and regulations.
GENERAL
REQUIREMENTS.
The piping, fittings, air
receiver tank, etc must be certified safe for at least the
maximum
Workk_g £_essuee of the _tht. Use hard worded or
threaded steel or copper pipes and cast iron fittings that are
certified safe for the unit's discharge
pressure and
temperature
DO NOT USE PVC PLASTIC iN THE
COMPRESSEDAIR
DISCHARGE
LINE Use pipe thread
sealant on all threads, and make up joints tightly to p_event
air leaks
CONDENSATE
DISCHARGE
PIPING.
Ifinstalling
a
condoners
discharge
line, the piping must be at least one size
larger than the connection,
as short and direct as possible,
secured tightly and routed to a suitable drain potht or waste
container
Condensate
must be disposed of in accordance
with local state, and federal laws and regulations.
WARNING
If an aRercooler,
_heck
valvl,
block valve,
or any other restriction
is added
to the
compressor
discharge,
instBll a properly-
sized ASME approved
safety/relief
valve
between
the compressor
discharge
and
the restriction,
INSTALLING
ELECTRICAL
WIRING
z_ WARNING
Electricallnstallationandserviceshould
be performed
by a qualified
electrician
who is familiar with all applicable
local,
state and federal laws and regulations.
GENERAL.
The motor rating, as shown on the motor
nameplate, and the power supply must have compatible
voltage, phase and hertz charactedstics.
WIRE SIZE. The electncal widng betweeri the power supply
and electric motor varies according
to motor horsepower and
other factors Install adequately
sized power leads to protect
against excessive voltage drop during start-up.
Refer to the
National Electdc Code (NEC) for information
on selecting
the
proper wire size and securing electrical connections
If you
connect additionat
eleclncat
equipment to _he same _r cult,
consider the total electrical
load when selecting the proper wire
size DO HOT USE UNDERSIZE
WIRE.
If wire size inforrNation is not available,
the wire sizes shown in
the following wire selection
chart can be used as a s_|e gt3ide,
if the distance does not exceed 50 feet (15 3 rn) For longer
distances,
constgt and electdcal contractor
or the Ioc81 electric
company
for reo3mmendations
Wire sizes shown in AWG (SWG)
AWG - Amencan
Wire Gauge
SWG - BdtJsh Imperial SLandard Wire Gauge
MAGNETIC
STARTER.
If the motor installed on your unit has
a motor reset button, it does not require a magnetic starter. If
the motor does not have this button and the unit does not have
a factory-inslalled
starter, install a magnetic starter with thermal
ovedoad protection
Follow the manufacturer's
instructions for
installation.
Ingersoll-Rand
cannot accept respons+bility for
damages
adsing from failure to provide adequate motor
prolectlon
FUSES.
Refer to the NEC to determine the proper PJse or
circuit breaker rating required. When selecting
fuses,
remember the momentary
starting current of an electdc motor
is greater than its fullload current.Tim_delay
or "slow-blow
_
fuses are recommended
PRESSURE
SWITCH. On units without a factory-installed
pressure switch, wire a pressure
switch in accordance
with the
appropriate
wiring schemat)c in the DIAGRAMS
section o1this
manual
Mount the pressure switch in accordance
with the
manufacturer's
recommendations.
The connecting
line to the
receiver tank must be as short and direct as possible,
and
ce_f_
saf_ tot at _east t_ max_um
wo_k_
p_ss_[e
Of
the unit
B_3LI_H

Publicidad

loading