DISPLAY DATA
DESCRIPTION
dEF.
no
It does not load the V2 standard data
SCor
Predefined programming for a typical sliding gate.
AntE
Predefined programming for a typical two-door gate
t.AP1
0.0" ÷ 2.0'
Gate 1 opening time
t.AP2
0.0" ÷ 2.0'
Gate 2 opening time
t.APP
0.0" ÷ t.AP1
Opening time of pedestrian gate
t.Ch1
0.0" ÷ 2.0'
Gate 1 closing time
t.Ch2
0.0" ÷ 2.0'
Gate 2 closing time
t.ChP
0.0" ÷ t.Ch1
Closing time of pedestrian gate
t.C2P
0.5" ÷ 2.0'
Leaf 2 closing time during pedestrian cycle
no
- Function disabled
r.AP
0.0"÷ 2.0'
Gate delay during opening
r.Ch
0.0" ÷ 2.0'
Gate delay during closing
C2rA
no/Si
Closing leaf 2 during delayed opening
t.SEr
0.5" ÷ 2.0'
Electrical lock operation time
no
- Lock is not energized (it corresponds to 0)
SEr.S
Si/no
Silent Locking Mode
t.ASE
0.0" ÷ 2.0'
Lock advance time
t.inv
0.5" ÷ 3.0"
Backlash time
no
- Backlash disabled (it corresponds to 0)
t.PrE
0.5" ÷ 2.0'
Pre-flashing time
no
- Pre-flashing disabled (it corresponds to 0)
t.P.Ch
0.5" ÷ 2.0'
Different closing pre-flashing time
no
- the closing pre-flashing time corresponds to t.PrE
Pot1
30 ÷ 100%
Motor 1 power
Pot2
30 ÷ 100%
Motor 2 power
SPUn
no/Si
Start off
t.P.So
0.5" ÷ 3.0"
Slowed down starting time
no
- Slowed down starting disabled
t.raL
0.5"÷22.5"
Slow down time
no
- Slow down disabled
t.CVE
0.0" ÷ 3.0"
Fast closing time after slowing down during closing
St.AP
Start in opening
no
- Start command is not available
ChiU
- Command close gate
PAUS
- Stop the gate and goes in pause
St.Ch
Start in closing
Stop
- Start command stop the gate
APEr
- Start command open the gate
tE.M
Si/no
Enabling the motor test
St.PA
Start in pause
no
- Start command is not available
ChiU
- Start command closes the gate
SPAP
Pedestrian in opening
no
- Pedestrian start command is not available
ChiU
- Pedestrian start command closes the gate
PAUS
- Gate goes in pause
Ch.AU
Automatic closing
no
- The automatic closing is not active (it corresponds to 0)
0.5"÷ 20.0'
- The gate closes after the setup time
Ch.tr
Closing after passage
no
- Closing after passage disabled
0.5"÷ 20.0'
- Gate stop for a time to be set between 0.5" to 20'
PA.tr
no/Si
Pausa dopo il transito
LP.PA
no/Si
Flashlight in pause
CITY1-ECD FUNCTION TABLE
48
DEFAULT
DEFAULT
MEMO
SCor
AntE
DATA
no
no
22.5"
22.5"
0.0"
22.5"
6.0"
6.0"
23.5"
23.5"
0.0"
23.5"
7.0"
7.0"
no
2.0"
1.0"
1.0"
3.0"
3.0"
no
no
no
2.0"
Si
Si
0.0"
1.0"
no
no
1.0"
1.0"
no
no
60
60
-
60
no
Si
1.5"
no
2.0"
2.0"
0.0"
1.0"
PAUS
PAUS
StoP
StoP
Si
Si
ChiU
ChiU
PAUS
PAUS
no
no
no
no
no
no
no
no