3.0 INSPECTION
3.1
FREQUENCY: Before each use visually inspect per steps listed in
section 3.2 and 3.3.
3.2
INSPECTION STEPS:
Step 1.
Inspect the Advanced Portable Fall Arrest Post for physical
damage. Look carefully for any signs of cracks, dents or
deformities in the metal. Make certain the post, brackets
and other components are not deformed in any way and
that they pivot correctly.
Step 2.
Inspect the Advanced Portable Fall Arrest Post for signs of
excessive corrosion.
Step 3.
Ensure the condition of the mounting surface will support
the anchor plate loads. An anchor plate to a deteriorated
surface should not be used.
Step 4.
Ensure the anchor plate is securely attached to the
mounting surface. See section 2.1.
Step 5.
Inspect each system component or subsystem (i.e. self
retracting lifeline, full body harness, etc.) per associated
manufacturer's instructions.
Step 6.
Record the inspection date and results on the 'Inspection
and Maintenance Log'.
3.3
If inspection reveals an defective condition, remove unit from service
immediately and destroy, or contact a factory authorized service
center for repair.
IMPORTANT:
Only Capital Safety or parties authorized in writing may
make repairs to this equipment.
Figure 12 - Using the Davit Arm