Honeywell Miller RA15-1 Instrucciones De Uso página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.4 RA30-1
Warnings and Limitations
• The RA30-1 roof anchor is designed for
roof-top installations on fully sheathed
roofs comprised of wood members. Do
not install on unsupported roof struc-
tures such as eaves or gable overhangs.
Do not install on facia boards.
• The RA30-1 roof anchor must be installed
at least 2 ft. (0.6m) from any roof edge.
• It is recommended that twelve (12) new
16d nails OR six (6) new ¼" x 2-½" (6.4mm
x 63.5mm) or longer lag screws be used
each time the anchor is installed. Roof
anchor must be inspected before each
installation.
• Maximum capacity is 310 lbs. (140.6kg),
including body weight, clothing and
tools.
Installation
1. Locate and mark solid roof members/support
structures (i.e., studs, joists, rafters, trusses,
etc.) under roof sheathing at the location
where the roof anchor will be installed.
2. Refer to Fig. 4 for proper setup. (Drawing is
for illustration purposes only -- Do not com-
bine nails and screws when installing the
RA30-1 roof anchor.)
3. Install the RA30-1 roof anchor with twelve
(12) 16d nails (six on each side) OR* six (6)
¼" x 2-½" (6.4mm x 63.5mm) or longer lag
screws (three on each side).
WARNING
Use all twelve (12) 16d nails OR all six (6)
¼" x 2-½" (6.4mm x 63.5mm) lag screws
to attach the RA30-1 roof anchor. All
nails/screws must pass through the
sheathing and into a support structure.
If this warning is not followed, the an-
chorage connection will be weakened
and serious injury or death could occur
in the event of a fall.
Attach to the O-ring only with a locking
snap hook, locking carabiner, or other
Honeywell-approved connector or con-
necting device.
12
3.5 RA35-1
Warnings and Limitations
• The RA35-1 roof anchor is designed for
roof-top installations on partially or fully
sheathed roofs comprised of wood mem-
bers. Do not install on unsupported roof
structures such as eaves or gable over-
hangs. Do not install on facia boards.
• The RA35-1 roof anchor must be installed
at least 2 ft. (0.6m) from any roof edge.
• It is recommended that six (6) new 16d
nails OR three (3) new ¼" x 2-½" (6.4mm
x 63.5mm) or longer lag screws be used
each time the anchor is installed. Roof
anchor must be inspected before each
installation.
• Maximum capacity is 310 lbs. (140.6kg),
including body weight, clothing and
tools.
Installation
1. Locate and mark solid roof members/support
structures (i.e., studs, joists, rafters, trusses,
etc.) under roof sheathing at the location
where the roof anchor will be installed.
2. Refer to Fig. 5a or 5b for proper setup.
3. Install the RA35-1 roof anchor with six (6)
16d nails OR three (3) ¼" x 2-½" (6.4mm x
63.5mm) or longer lag screws in the anchor
holes designated.
WARNING
Use all six (6) 16d nails OR all three (3)
¼" x 2-½" (6.4mm x 63.5mm) lag screws
to attach the RA35-1 roof anchor. All
nails/screws must pass through the
sheathing and into a support structure.
If this warning is not followed, the an-
chorage connection will be weakened
and serious injury or death could occur
in the event of a fall.
Attach to the O-ring only with a locking
snap hook, locking carabiner, or other
Honeywell-approved connector or con-
necting device.

Publicidad

Tabla de contenido
loading

Tabla de contenido