Preparing Respirator For Use; Donning The Apparatus; Regulator Check; Donning The Facepiece - MSA PREMAIRE CADET Instrucciones

Ocultar thumbs Ver también para PREMAIRE CADET:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREPARING RESPIRATOR FOR USE

Note: Before donning, check that the regulator quick-con-
nect seal ring is seated properly in its groove, and that it
is not torn, gouged, or nicked.
Before donning and using the respirator, the apparatus
must be tested for any leaks in the supplied-air sys-
tem. The respirator must be pressurized to conduct
the tests. See the user instruction manual for the
required leak test procedures. Failure to follow this
warning can result in serious personal injury or death.
1. UPON RECEIPT, thoroughly check the respirator
before use. Check the facepiece, regulator, hoses, and
all fittings for shipping damage. Replace any damaged
components.
2. BEFORE EACH USE, inspect the facepiece, regulator,
and hoses for wear. Replace any damaged compo-
nents. See inspection guidelines.
3. If using the escape cylinder option, refer to
P/N 497230 for instructions for donning the shoulder
strap.

DONNING THE APPARATUS

1. Remove the facepiece from the case.
DO NOT use a cover lens in a high-temperature envi-
ronment, such as firefighting. High temperatures may
distort the cover lens. Or, moisture trapped between a
cover lens and the facepiece lens may condense and
distort vision. Always remove the cover lens before
donning the facepiece. Failure to follow this warning
can result in serious personal injury or death.
DO NOT use the PremAire System for firefighting.
Failure to follow this warning can result in serious per-
sonal injury or death.
2. Fasten the waist-strap
and pull it tight for a
snug fit. The waist-strap
end must be tucked in
and lay flat across the
body.
WARNING
WARNING
WARNING
DONNING

REGULATOR CHECK

1. Grasp the mask mounted regulator and push shut-off IN.
Note: The 1/4 Turn Second Stage MMR Regulator has a
shut-off button on one end of the regulator. The Firehawk
Second Stage MMR Regulator has a slide button (top
release button) on top of the regulator.
2. Connect the air-supply hose to the inlet to initiate air flow.
3. No air should flow from the regulator. If it does, repeat
steps 1 and 2.
4. Disconnect air-supply. Slowly bleed off pressure.
The apparatus must be checked and corrected for
proper operation by an MSA trained repairperson
before using. Failure to follow this warning can result
in serious personal injury or death.
Note: Before donning, check that the regulator quick-con-
nect seal ring is seated properly in its groove, and that it
is not torn, gouged, or nicked.

DONNING THE FACEPIECE

DO NOT wear eyeglasses under the facepiece. The
temples or sidebars on eye glasses will prevent an air-
tight seal. if you must wear glasses, install the specta-
cle kit. Failure to follow this warning can cause inhala-
tion of contaminated air, resulting in serious respirato-
ry injury or death.
1. Extend the facepiece
straps fully. Place neck-
strap around your neck
and don the facepiece
by inserting your chin
first.
7
WARNING
WARNING
TAL 706 (L) Rev. 8 - 800810

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido