Descargar Imprimir esta página

Fein Slugger JMU 137 QW Instrucciones De Uso página 14

Ocultar thumbs Ver también para Slugger JMU 137 QW:

Publicidad

Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000261-003.book Page 14 Thursday, April 27, 2017 7:47 AM
en
14
Filling the coolant container.
Prevent the flow of liquid along the cable into the socket outlet or into the core
WARNING
drill unit, as this can lead to electric shock. Tie a bow in the cable near the plug,
so that any liquid can drip off.
Do not use the magnetic base drill unit if the cooling lubricant system is defective. Check for
proper seal against leaks and for cracks in the hoses. Prevent liquids from entering or penetrat-
ing electrical components.
Only use a coolant-lubricant emulsion (oil in water) as the cooling agent.
Observe the manufacturer's instructions on coolant.
Filling the mounted coolant container
(figure 4)
Unscrew the cap from the coolant container.
Fill in pump-feedable cooling lubricant,
e.g. Slugger cutting oil.
Screw the cap onto the coolant container
again.
Fig. 4
Upper closing cap
2.
3.
1.
Coolant container

Publicidad

loading

Este manual también es adecuado para:

Slugger jmu 137 mqwSlugger jmu 137-2 qwSlugger jmu 137 qw serieSlugger jmu 137 mqw serieSlugger jmu 137-2 qw serie