23
Starting and stopping the drill motor
Fig. 14
(figure 14).
To start the drill motor with clockwise rota-
tion, press the button with the „
" symbol.
The drill motor starts with the highest speed.
The last set speed is automatically stored
(Memory Function). To start the power tool
100
%
with the last set speed, press and hold the
l
85
%
l
75
%
l
60
%
button with the
symbol, and then press
l
50
%
l
the button with the
symbol.
25
%
l
To lower the speed, press the „
" symbol.
To increase the speed, press the „
" sym-
bol.
To stop the drill motor, press the „
"
100
%
l
85
%
symbol.
l
75
%
l
60
%
l
50
%
Do not stop the drill motor during the drilling
l
25
%
procedure.
l
To start the drill motor with counterclock-
wise rotation, press the button with the
" symbol. The drill motor will run as
long as the button is pressed.
When the power supply is disconnected
Memory Function
while the drill motor is running, a protective
circuit prevents automatic restarting of the
drill motor. Restart the drill motor again.
In case of overload, the drill motor automati-
cally stops and must be restarted again.