Introduction
Controls, Connectors and Indicators
Ceiling Mount
Cover
8 7
9
1
2
3
(Connector side)
1
[VIDEO OUT] Coaxial Cable Connectors
Output connector of a composite video signal (1 V(p-p))
with an output impedance of 75 Ω, to be connected to a
switcher, etc.
2
[AC ` 24V INPUT] Connector
Connect to a 24 V AC power supply.
3
Cover Position Alignment Mark
When attaching the cover, use this mark to align its final
position correctly.
4
Locking Screw
Tighten this screw to fasten the camera clamping bracket
*
.
5
Safety Wire Hole
To prepare for possible dropping of the camera, pass the
wire from the ceiling slab or channel through this hole.
6
Alarm Input Terminals (CN26)
Input terminals for Alarm 2, Alarm 3 and Alarm 4.
Connect the provided cables to these terminals.
P. 15
Pin No.
Signal Name
1
Alarm input 2
2
GND
3
Alarm input 3
4
GND
5
Alarm input 4
6
GND
E-6
0
6
5
4
Color of Cable
Brown
Red
Orange
Yellow
Violet
Gray
I Camera body
9
Pin 1 of alarm output terminal
(CN24)
(Terminal Pin Layout)
7
[ALARM I/O] Input/Output Terminals (CN23)
Terminals for Alarm input 1 and Alarm output 1.
P. 15
Pin No.
1
Alarm output 1 (N.OPEN)
2
Alarm output 1 (COM)
3
Alarm output 1 (N.CLOSE)
4
Alarm input 1
5
8
[CONTROL] Terminals (CN22)
Connect to a RM-P2580 remote control unit.
Pin No.
1
2
3
4
9
Alarm Output Terminals (CN24)
Output terminals for Alarm 2 and Alarm 3.
Connect the provided cables to these terminals.
P. 15
Pin No.
1
Alarm output 2 +
2
Alarm output 2 –
3
Alarm output 3 +
4
Alarm output 3 –
8
Pin 1 of CONTROL terminal
(CN22)
7
Pin 1 of ALARM I/O terminal
(CN23)
6
Pin 1 of alarm input terminal
(CN26)
Signal Name
GND
Signal Name
TX +
TX –
RX +
RX –
Signal Name
Color of Cable
White
Orange
Gray
Mark
A
B
C
D
Red