Chapter 3
Tab. 1: Enable
zone and safe
switch off
distance
IN40-D0101K
Tab. 2: Enable
zone and safe
switch off
distance
IN40-D0202K
62
Product description
At an ambient temperature of 20 °C, with the safety
switch surface mounted, with a standard plate in
compliance with EN 60 947-5-2 (45 × 45 × 1 mm
IN40-D0101K and IN40-D0202K or 24 × 24 × 1 mm
for IN40-D03..) the following enable zone is typically
achieved with different materials:
Material
Steel FE360
Stainless
steel 1.4302
(V2A)
AlMg 3G22
Al 99 %
CuZn 37
Cu
Material
Steel FE360
Stainless
steel 1.4302
(V2A)
AlMg 3G22
CuZn 37
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice • 8010934/YTC9/2016-04-01
IN40-D0101K
Enable zone
Lower limit
Upper limit
≥ 10.0 mm
≤ 15.0 mm
7.5 mm
13.2 mm
2.0 mm
5.8 mm
1.4 mm
5.0 mm
2.3 mm
6.2 mm
0.8 mm
4.3 mm
IN40-D0202K
(cylindrical M30)
Enable zone
Lower limit
Upper limit
≥ 6.0 mm
≤ 12.0 mm
3.7 mm
8.4 mm
1.0 mm
4.7 mm
1.2 mm
5.1 mm
Operating Instructions
IN4000 Standard
3
for
3
Safe
switch off
distance
30 mm
Safe
switch off
distance
30 mm