Auxiliary Input: This parameter controls how the drive will react when the AUX INPUT control terminal is
used.
•
Fault with High (default): In this setting, the drive output will stop when the external switch closes.
•
Fault with Low: In this setting, the drive output will stop when the external switch opens.
In both cases, Fault F26 will be displayed on the monitor. When the switch moves to the opposite position, the
drive output will restart after 30 seconds.
Refer to
"Drive Control Using an External Device (Auxiliary Input)" on page 37
Units Selection: Select either kilowatts or horsepower.
Available Firmware
Provides the capability to download the latest drive firmware using a mobile device and then update the
SubDrive/MonoDrive Connect.
System Monitoring
This screen provides real-time monitoring of the system including:
•
System Information (Drive Model, Hardware Version, Software Version)
•
System Status: Running, Idle, Faults
•
System Pressure (pressure transducer required)
•
Built-In Duplex Alternator Status
•
Motor Speed
•
Input Voltage
•
Output Current
FE Connect Mobile Application
for more information.
COMMUNICATIONS
35