INSTALLATION PLANNING

Planning Considerations

The planned usage of the overall
system will determine which options
STEP 1
and control methods are
appropriate, as well as how the VFD
should be installed and
Plan System
programmed. Refer to the following
Goals
pages for examples of how the
system might be used.
System options define and automate
features that support the intended
STEP 2
operation. These features may
require specialized control methods
and programming. For more details,
Identify
refer to "Drive Configuration" on
Options
page 24, "Operation" on page 29.,
and "Advanced Application Options"
on page 37
STEP 3
The SubDrive Connect supports
several methods for automating
pump motor speed control. Refer to
Select
"Drive Configuration" on page 24
Control
for possible control setups.
Methods
The overall function of the system
STEP 4
directly affects where and how the
VFD should be mounted. Refer to
Install VFD
"Physical Installation" on page 15 for
Hardware
guidelines.
The selected motor application,
STEP 5
along with the control method(s),
determines how the VFD should be
Install
connected. Refer to "Electrical
Wiring
Installation" on page 17 for more
information.
The VFD can be quickly and easily
programmed for most standard
operations. Refer to "Drive
STEP 6
Configuration" on page 24. Advanced
features or options may require
additional adjustments to achieve the
Program
desired performance. Refer to
Parameters
"Advanced Application Options" on
page 37 and to "Drive Configuration
Using the FE Connect App" on
page 32.
Intended Function:
Constant Pressure Water Systems
Pressure Boosting
Type of Automation:
Desired Protection:
System Response
Broken Pipe
Bump Mode
Underload
Steady Flow
Motor Ground Fault
Drawdown
Moisture Sensor
Run/Speed/Stop:
Communication:
Hand/Auto
FE Connect Mobile App
Transducer/Sensor
Drive-to-drive
Potentiometer
Aux Control Input
Switches/Floats
Relay Out
Location:
Distance to the Well:
Drive Size:
Inside
Clearance
Drilling
Outside
Power Connections:
Conduit Rules:
Grounding
Routing
Inputs
Separation
Outputs
Basic Programming:
I/O Setup:
Application
Input Functions
Motor Ratings
Output Functions
Setpoints
INSTALLATION PLANNING
Planning Considerations
Hardware Application:
Submersible
Surface Pump
Single- or Three-Phase
Multi Pump:
Duplex Alternator
Lead/Lag
Climate Control:
Temperature
Wire Sizes
Filtering Requirements
Moisture
Control Circuits:
Feedback Inputs
Relay Outputs
Communications
Other Available Options:
Enable Features