Power Circuit And Motor Connections - Franklin Electric SubDrive 50 Manual Del Usaurio

Ocultar thumbs Ver también para SubDrive 50:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Power Circuit and Motor Connections

Drive is suitable for use on a circuit capable of delivering not more than 5000 RMS symmetrical amperes,
250 volts maximum.
Verify that the dedicated branch circuit for the drive is equipped with a properly-sized circuit breaker. Refer
to
"Input Wire and Fuse Sizing" on page 18
Verify that the power has been shut off at the main breaker.
1.
Feed the motor leads through the opening on the bottom right side of the drive and connect them to
the terminal block positions marked
to 15 in-lbs (1.7 Nm).
2. Feed the 230 VAC power leads through the larger opening on the bottom left side of the drive and con-
nect them to the terminals marked L1, L2, and
NOTE: These terminals accept wire sizes from 6 to 20 AWG and should be tightened to 15 in-lbs (1.7 Nm).
for minimum breaker size.)
(Green Ground Wire), Red, Yellow and Black. Tighten terminals
. Tighten terminals to 15 in-lbs (1.7 Nm).
ELECTRICAL INSTALLATION
Power Wiring Connections
21

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido