Auxiliary Input

This parameter controls how the controller will react when the AUX
INPUT control terminal is used. This can be set as either Fault with High
or Fault with Low.
Default: Fault with High
[Reference "AUX In" screenshot as a supporting figure]
Moisture Sensor
This parameter controls how the controller will react when the WET
SENSOR control terminal is used. This can be set as either Fault with
High or Fault with Low. The Fault with High condition supports the
Franklin Electric Moisture Sensor device. The Fault with Low condition
can be used with other unpowered dry contact switched input devices.
Default: Fault with High
[Reference "WFS Config" screenshot as a supporting figure]

Monitoring

This screen allows for real-time monitoring of the system including:
• System Status
• System Pressure (analog pressure transducer required)
• Built-In Duplex Alternator Status
• Motor Speed
• Input Voltage
• Output Voltage
• Output Current
• System Information (Drive Model, Hardware Version,
Software Version)

Logs

This screen allows the Fault History and Configuration Change History
logs to be viewed and emailed. This screen also displays the total Drive
On Time and Motor Run Time along with the actual date and time when
each log entry occurred.
SubDrive/MonoDrive Connect
AUX In
WFS Config
35