NB: The configuration is saved if the product
is switched off. It is lost in case of modification of the
pairing (addition of sensors, replacement, removal).
§5.5.11.2
The "Configuration" sub-menu is entered by pressing
the "OK" button briefly (item E, fig. 1) when the
"Configuration" icon is highlighted.
A
B
F
H
K
A
Number of dynafor™ Transmitter WL models present
on the channel.
B
Number of dynafor™ Pro models present on the
channel.
C
Number of dynafor™ Expert models present on the
channel.
D
Number of dynafor™ HHD or DMU models present on
the channel.
E
Number of dynafor™ AL128 models present on the
channel. Not used when using this product.
F
Configuration table:
• Lines representing the display devices
• Columns representing the sensors
G
Identification of equipment (last nine digits in serial
number)
H
Master display device reference.
I
Green tick: Sensor displayed on the display device
corresponding to its line.
J
Red tick: Sensor not displayed on the display device
corresponding to its line.
K
Lower banner showing the selected sensor
information (5.5.2).
The table is entered by pressing an arrow button.
The navigation is done by using the left, right, up and
down arrow buttons.
Press the "OK" button to change the tick status.
NB: Up to four sensors and four display devices
are displayed.
To return to the main menu, hold down (for one second)
the left button.
C
D
E

5.5.12. Thresholds menu

NB: The thresholds are saved if the product is
switched off, unless the network configuration (addition
of sensors, replacement, removal) is modified.
§5.5.12_a
NB: The thresholds are always set to gross
values.
The "Thresholds" menu is entered by pressing the "OK"
button briefly (item E, fig. 1) when the "Threshold" icon
is highlighted from the main menu.
G
I
J
C
D
E
A
Top banner, containing the information described in
5.5.2
B
Instantaneous measurement
C
Threshold number
D
Trip direction (up, down or not active)
E
Sensor serial number for the threshold setting
F
Set threshold value
G
Hysterisis value. This hysteresis corresponds to the
load percentage required to deactivate the threshold.
Example: threshold set at 500 daN, 10% hysteresis.
Exceeded at 500 daN, disengagement at 500 –
10%x500= 450 daN).
H
Activation of the built-in buzzer if the threshold is
tripped
I
Number of recorded overruns
J
Duration of the total threshold overrun
K
Delete the set threshold
Up to five thresholds can be configured.
To configure a threshold, select a line with the up and
down buttons. Confirm the line selection by pressing
the "OK" button.
The line is navigated by pressing the left and right
buttons.
The up and down buttons are used to set the
parameters:
• Trip direction:
F
G
H
I
J
GB
A
B
K
15