5.2. Installation of the associated
sensor(s)
GB
During installation, it is imperative to follow the
recommendations
operation and maintenance manuals of the sensors.

5.3. Starting up the sensor

Always switch on the sensor(s) before switching on the
hand held device, otherwise the hand held device will
not be able to establish the radio link.
See the sensor manual for information on starting it up.
When the power is turned on, the two red LEDs start to
flash simultaneously.

5.4. Starting up the product

The dynafor™ HHD hand held device is started up by
pressing and holding (for three seconds) the ON/OFF
button on the front panel (see figure 2), until the home
screen appears.

5.5. Function

5.5.1. First use

NB: The multiple configuration consists in
connecting up to four sensors. The sensors can have
different capacities. (For more than four sensors, the
PC Monitoring Software connection option is required.)
When the product is switched on, it automatically
searches for sensors in its environment, on a defined
channel. If the channel is already occupied, it is
automatically incremented. Up to 10 channels, and
therefore 10 configurations, are available. The search
time for the devices is one minute. Once the search is
complete, the product switches to the next screen:
8
mentioned
in
the
installation,
The navigation is done by using the up and down arrow
buttons. (See figure 1.) Sensors that are not paired are
ticked red by default.
Pressing the OK button (see figure 1) selects the sensor
for pairing. The tick will then turn green.
All sensors can be selected by pressing "Select all".
After selecting them all, holding down the "OK" button
starts the pairing of the sensors.
The pairing of a sensor is confirmed when the two
LEDs on the front of the sensor are activated for three
continuous seconds.
Once the sensor(s) have been paired, the product
automatically switches to the main display.
§5.5.2
To return to this screen for further pairings, see chapter
5.5.11.1.

5.5.2. Single-sensor main display

B
C
N
L
J
K
A
Measurement
B
Tractel logo
C
Unit of measurement
D
Measurement filter (see 5.5.8.2)
E
Threshold trip filter (see 5.5.8.2)
F
Built-in buzzer (see 5.5.12)
G
Product battery indicator
H
Status of the connection to the sensor
I
Time
J
Sensor logo (differentiated according to the dynafor™
Pro, Expert and Transmitter WL models)
K
Sensor batteries indicator
E
D
F
G
H
I
A
M