Press the "OK" button to make the message disappear.

5.5.15. Sensor batteries low

If one of the sensors has a low battery, the product will
display the message "Low battery".
Press the "OK" button to make the message disappear.

5.5.16. Display unit battery low

If the product has a low battery (20%), the product will
display the message "Low battery".
Press the "OK" button to make the message disappear.
It is advisable to recharge the product. (See 7.1.)

5.5.17. PC connection

The product can be connected to the PC to interface
with the compatible software described in chapter 4.
Associated equipment. Refer to the corresponding
manuals.

5.5.18. Slave configuration

NB: There can only be one master in any
configuration. Always switch on the slaves before the
master. A sensor is always considered a slave.
The slave configuration mode is an advanced mode
that lets you associate several display devices together,
for example two dynafor™ HHD hand held devices.
The slave display device will then repeat the information
sent by the master device.
To do this, switch the product to slave mode in the
sub-menu Parameters – General. (See 5.5.8.2.) The
product restarts on exiting the sub-menu. When the
product is switched on, the loading screen shows M for
Master, and S for Slave.
It is then no longer possible to pair devices on the slave
device or to manage the sensor modes.
The master display unit can perform pairing (see
5.5.11.1) and will find the slave device.
The master display unit can perform the network
configuration. (See 5.5.11.2.)
The slave product then displays the sensors configured
on the master device.
NB: All other functions (tare, peak load and
thresholds, etc.) are accessible.
NB: If the master device is turned off, the slave
device will lose the connection and display "XXXX".
NB: If the slave device is turned off and then on
again, it will display "XXXX". The assembly of products
(slave(s) then master) need to be reinitialised.
NB: If a slave device is switched off, the master
device is not affected.

5.6. Turning the product off

To turn the product off, press and hold the on/off button
for three seconds without pressing too hard.