Emerson HF948BS02 Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Wall Control Installation
6.9
NOTE: The WHITE neutral wires inside the electrical
box must be connected together for proper operation
of the wall control. NEVER connect the WHITE neutral
wires to the Wall Control (Figure 26).
WARNING
!
Do not connect any neutral (WHITE) wire to this control.
Incorrect wiring WILL damage this control.
6.10
Carefully tuck all wires and wire connectors into the outlet
box and position the Wall Control onto the outlet box
(Figure 27).
6.11
Place the previously removed faceplate onto the Wall
Control.
Assemble the faceplate to the Wall Control using the two
previously removed 6-32 screws (Figure 28).
(Continued)
DO NOT CONNECT ANY WIRES FROM
WALL CONTROL TO THESE WHITE
NEUTRAL WIRES
Figure 26
POSITION THE WALL
CONTROL INTO THE
OUTLET BOX
WALL
CONTROL
Figure 27
PREVIOUSLY REMOVED
6-32 SCREWS (2)
Figure 28
16
TO FAN
MOTOR LOAD
TO 120VAC
SOURCE HOT
WIRES TUCKED INTO
OUTLET BOX
PREVIOUSLY REMOVED
FACEPLATE
U.L. Model No.: HF948 & HF956

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hf948w02Hf956bq02Hf956bs02Hf956w02

Tabla de contenido