Installation Of Vent System - Jøtul GF 100 BF2 Instrucciones Para Instalación

Ocultar thumbs Ver también para GF 100 BF2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.0 Installation of vent
system
For further information (vent system Ø 100/150 mm): see manual
for Balanced flue system.
Before mounting carefully read the section about the vent system.
Pay special attention to fig. 3A and the text in the manual for the
conversion kit, section: Adjusting the air regulator.
Set up the product in a «dry run» with the vent system loosely
connected.
Mark off on the wall where the vent pipe is to be.
If the wall is made of brick, the pipe can be fed directly through the
wall. If the wall is made of wood, a wall shield must be used.
6.1 Installation of wall shield (See fig. 2)
When installing a wall shield (fig. 2F), make a square opening
in the wall with dimensions 250 x 250 mm. The opening may
be strengthened with a wooden frame, if the wall requires
reinforcement.
Do not fill the hollow area between vent pipe and wall/ceiling
with insulation or similar material, as it is important for air
to circulate around the pipe.
Pull apart the 2 halves (F) of the wall shield.
Attach one half with 4 screws on the inside of the wall (E)
and the second half with 4 screws on the outside of the
wall (G).
If you wish to hide the wall shield on the inside wall, use the
cover plate (not included) (D) and fasten with 4 screws.
In the case of long pipes, it is recommended that the pipes be
attached to the walls using brackets (not included).
6.2 Vent system (Ø100/170 mm) for
installation straight out through wall
(fig. 2)
Pos: Qty:
Description
H-M
1
Ex h a u s t h o o d fo r h o r i zo nt a l ve nt w i t h
410 mm pipe length.
6
1
Adapter 45
0
N
1
Exhaust hood protection.
1
Bag of screws (3 screws per pipe set) and 4 screws
for exhaust hood, plus 4 screws for exhaust hood
protection.
1
Heat resistant sealant (not supplied)
Installation
1.
Check that the gasket around the flue outlet is intact. This is
attached using 4 x Ø4.2mm screws.
2.
Undo the screws and attach the adapter (fig. 6) using the
same 4 screws, so that the pipe remains horizontal. Use a
heat resistant sealing agent to seal all joints.
3.
The pipe length on the exhaust hood (L-M) should be adjusted
so that the stove is at least 70mm from the wall (fig. 1). Note
that the innermost pipe should be 10mm longer and the back
of the hood should rest against the outer wall.
4.
Screw the four screws (H) that attach the back piece (I) to the
exhaust hood. Feed the outer pipe (M) in through the wall
from the outside, and fit the back piece on a smooth outer
wall using 4 screws from the bag (J) .
5.
Make sure that the horizontal section of the flue pipe has a
minimum incline of 2%.
6.
The exhaust hood (K) with the inner pipe (L) is fed in through
the wall from the outside. The hood is screwed to the back
piece and the pipe is connected to the stove adapter on the
back of the stove.
7.
If the position is less than 3m above ground level (measured
on the outside of the house), the exhaust hood must be fitted
with the hood protection (N) on the outside of the house
using 4 enclosed screws (O).
6.3 Vent system (100/170 mm) for
installation straight up and out through
wall (fig. 2)
Pos: Qty:
Description
H/M
1
Ex h a u s t h o o d fo r h o r i zo nt a l ve nt w i t h
410 mm pipe length.
B
1
Pipe length 500 mm (optional equipment)
C
1
Pipe bend 90
6
1
Adapter 45
0
N
1
E x h a u s t h o o d p r o t e c t i o n , s t a n d a r d
355 x 355 x 203mm.
1
Bag of screws (3 screws per pipe set) and 4 screws
for exhaust hood, plus 4 screws for exhaust hood
protection.
1
Heat resistant sealant (not supplied)
Installation
1.
Check that the gasket around the flue outlet is intact. This is
attached using 4 x Ø4.2mm screws.
2.
Undo the screws and attach the adapter (fig. 6) using the
same 4 screws, so that the pipe remains vertical. Use a heat
resistant sealing agent to seal all joints.
3.
A 500mm pipe may be used first or a 90° bend and then pipe
out. Pipe joints are fixed with three coach bolts (Ø 4.2mm).
4.
Remove the 4 screws (H) that are holding the back piece (I) in
place on the exhaust hood. The pipe length on the exhaust
hood (L-M) should be adjusted so that the stove is at least
70mm from the wall (fig. 1). Note that the innermost pipe
should be 10mm longer and the back of the hood should rest
against the outer wall. Feed the outer pipe (M) in through the
wall from the outside, and fit the back piece (I) on a smooth
outer wall using 4 screws from the bag (J).
5.
Make sure that the horizontal section of the exhaust pipe
has a minimum incline of 2%.
6.
The exhaust hood (K) with the inner pipe (L) is fed in through
the wall from the outside. The hood is screwed to the back
piece and the pipe is connected to the pipe bend on the back
of the stove.
7.
If the position is less than 3m above ground level (measured
on the outside of the house), the exhaust hood must be fitted
with the hood protection (N) on the outside of the house
using 4 enclosed screws (O).
6.4 Adjusting the air regulator
If the exhaust hood is closed in area A (see fig. 3) the air regulator
must be adjusted. Follow the conversion kit manual: Adjusting
the air regulator.
6.5 Mounting the log set