EB TECHNOLOGY START S10 Instrucciones Y Advertencias Para El Instalador página 35

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.16 Connection of the KEY LOCK - NEW LOCK SYSTEM
13
14
15
16
17
+
3.17 Connection of the Mechanical edge:
31
32
NOLOGO
3.18 Connection of the MOTOR with ELECTRO-MAGNETIC BLOC
If the electro-magnetic block is available, go to function S26 and put in 1 and make as follow:
Set up
Value
S 26
1
When this function will be activated and the motor is
working, the output of the KEY-LOCK will be powered,
this permet the brake and the correct working of the
gate.
3.19 Check of the connections
Check:
The tension in the terminal board , if all led are turned on (Normally closed), check all securities, right direction of the gate
(it opens first). When the control unit is powered, the L.E.D. (inputs) are turned on when in the input the contact is closed.
The red l.e.d. in the inputs CLS2 - OLS2 - CLS1 - OLS1 - PHOTOA - PHOTOB - STOP are always lit on.
The green l.e.d. in the inputs START / PARTIAL OPENING are always turned off.
Here you can see the connections of the key-lock.
18
19
The function S 26 should be programmed to "0":
-
S 26
S 28
Connection of the ALT control
Stops the automation and activates an inversion of direction for approxima-
tely 1.5 seconds.
Description
ELECTRO-MAgNETIC
BLOC
CLS2
OLS2
CLS1 OLS1 PHOTOA PHOTOB STOP START PED
Set up
0 -
Activate the KEY LOCK
1 - Deactivate
KEY LOCK
0 - Power Supply 12V - Power Supply 12V key lock
1 - Power Supply 24V - Power Supply 12V key lock
Set up
0 - mechanical edge Deactivate (Default)
S 27
1 - 8K2 contact
2 - 2 mechanical edge 8K2 connected in parallel
3 - N.C. contact
13
14
15
16
+
Description
the KEY LOCK
(Default)
Power:
Description
17
18
19
-
11
MOT
MOTOR

Publicidad

Tabla de contenido
loading